Oil, gas is now two types of power are urgently needed in many occasions, they make extensive use of oil burners and gas burners are also more scope to get the application, then the gas burner Troubleshooting and Repair
	Biogas burners Troubleshooting and Repair

Biogas burners Troubleshooting and Repair
May be due to clogging of the burner may bias the combustor discharge, and the nozzle constituting no; agglutination caused by water pipes are not strong flame. Cleaning method: clear burner; burner nozzle adjustment; cleaning pipes and condensate water sump device. Even flame was blue, from the fire does not burn, or although the power point, but can not automatically cited. This situation often occurs early in the new pool feed or just refueling test fire of the old pool stage, indicating that no more methane gas content, usually a few days to normal. Blue flame, flame length and flying weakness. The reason may be too large or throttle opening switch is closed during combustion, resulting in less air once more biogas formation. Cleaning method: turndown switch or door open wind, air and collaborative biogas appropriate. Blue with yellow flame, the flame is short and large noise. The reason is that when burned gas, more air. Cleaning method: a large open throttle switch or down. Small fire cooktop, nozzle sparkle. The reason may be: lack of momentum gas, backfire excessive fire-hole formed therein; ejector tube blockage, impede gas discharge. Cleaning method: large switch open damper; eradicate obstacles. Flames spread evenly, no outer burner fire. The reason may be: outer ring fire holes corrosion, clogging; lack of gas supply, may not work with air; cleaning methods: thermal plate should be clear; large switch open, the door winds tone. Common faults and repair, gas lamp mantles gas lamps simply break the fall. The reason may be: refractory clay head broken, the fire center hole; gas pressure is too high; there is no mantles well, by the sensation when lighting. Cleaning method: before the light control pressure rated pressure; attention maintenance cover glass, to avoid collision mosquitoes flutter. Biogas numerous, but does not light, white light or no redness. The reason may be: nozzle diameter is too small or blocked; the nozzle is too large, the lack of primary air ejector; aperture position of the damper is not adjusted; mantles quality is not good or moisture. Cleaning method: to increase the amount of biogas; intake air flow rate scheduling; replace mantles. Outer mantle shelf open flames. The reason may be: excessive methane; lack of primary air. Cleaning method: turn down the intake valve, or alternatively a small pressure drop gas nozzle; schedule into the wind.