Welcome to visit BNTET Burner website!

NEWS

Leaks boiler burner

Writer: admin Time:2021-11-23 00:00 Browse:

The gas burner is a fuel and air into the furnace continuously, rational organization of the pulverized coal flow, and allowed to mix well, rapid and stable ignition and combustion of a burner apparatus. With the view of leaks boiler burner
	Leaks boiler burner

Leaks boiler burner
However, please note that when a sense of photoelectric eyes back into the electric eye sockets, electric eyes photosensitive part should be toward the front. No temperature near the burner is too high, or else the burner portion of the assembly constituted damage, especially in the control box. Near the boiler burner should be kept clean, no accumulation of debris, to avoid being sucked burner, constitute a loss. Includes two gas leak terms, it refers to a gas leakage through the conduit to the environment, through the solenoid valve spool gas finger end facing the furnace leaks. Perhaps poisoning caused by environmental exposures, job site explosion incidents, must attach great importance. To ensure pipe seals for pipeline leak detection, pipeline leak to be cleaned if the party sustainable use of punctuality; secondly, to avoid the concentration of gas poisoning and constitute an explosion, the ventilation requirements of the job site: with vents and forced ventilation equipment; other require job site to prevent fireworks, explosion-proof electrical parts. Perhaps the furnace leak caused an explosion in the furnace. There are three processing furnace leak ways: one is to strengthen the pre-time hair and hair amount, blow-off or diluted gas furnace; second gas line is selected two solenoid valves in series configuration, system reliability trek; is the use of three line leak detection equipment, for burning the gas line before the detection, if the amount of gas leaks arrival i.e. confessed burner operation. Gas leak prevention measures is a peripheral control, are generally not included burner body control. In the new economy, flexibility, forge ahead, never pregnant with understanding and enthusiasm, sustained beyond their own, continue to exceed customer expectations. Burner application notes, and now together look. Coupling a peripheral circuit wiring diagram wiring please press control system for the boiler temperature, pressure, and water level automatic control is completed. Suction pipe near the bottom of the tank can not, there should be kept a distance of 80-120mm, fueling the tank should be closed to the front burner, before being filtered through the fuel oil injection, 20 minutes after fueling start from scratch talent. Before the hydraulic system must not leak and leak, recommendations Burner power plant, also needs to check whether the fuel tank is sufficient. Damper should match the size of the nozzle specifications, when the power plant boiler using burners, since the debugger is inconsistent with the boiler and the boiler burner factory, it is generally appropriate to adjust the throttle demand, sometimes the demand for the replacement of nozzle spray angle and specifications.