Gas burner highlight of energy conservation, as well as safety technology, the burner manufacturers take you to view and learn more about the rules boiler burner
	View and rules boiler burner

View and rules boiler burner
When people stop and shift down, the opposite sequence at the time of power at this time the operator shall: Close combustion control button; then turn off the fan button; power off button) the shutdown operation. Shutdown longer the case the operator should shut off the gas line valves, prevent the boiler burner gas leak phenomenon. Faced with air pollution emission standards, environmental policy after another, all over the country have launched a move boiler "coal to gas", the selection of heavily polluting coal-fired boilers, gas boilers to switch to clean environmentally friendly today we introduce the use of boiler burners What should pay attention to? Damper should match the size of the nozzle specification. When using the burner, because the inconsistent with debugging boiler burner and boiler factory, it is generally appropriate to adjust the throttle demand, sometimes it needs replacement specifications suitable nozzle angles and eruptions. Suction pipe near the bottom of the tank can not, should be maintained in the interval 80--120mm. Fueling the tank should be closed to the front burner, before being filtered through the fuel into the fuel tank, fuel injection start from scratch after 20 minutes talent. Oil spills and oil system must not leak. Before initiating combustion engine to see if the fuel tank is sufficient. See punctual boiler burner tube, impeller, and the combustion flame detector electrode, eradication oil and coke. In particular flame detectors should be kept clean and wet. Before combustion, the demand for some time with a pre-blowing, the furnace and the flue gas blow-off I or dilution. Because the noncombustible gas to prevent more than remain in the furnace burner operation, if no pre-blowing and burning, there is a danger of explosion. The residual gas blow-off demand or diluted with clean, to ensure that the concentration of the gas blast is not within the limits. Pre-blowing time of the furnace structure and the amount of hair is generally about 15 to 60 seconds is provided. Gas demand control solenoid valve is a normally closed type, power down, active close cut off the gas supply. Solenoid valve closing time care ≤5s. These contents is operating the boiler burner should be noted that, expect to see in the use of pay more attention, the correct operation of the boiler burner. In the use of oil burners, Amano is important, so we asked the following rules to: set the burner room: required to have special vents, vent settings to fit local requirements. The room should be kept clean. Fuel: burner fuel to fit the requirements of technical parameters.