Welcome to visit BNTET Burner website!

NEWS

Mode of operation of single fire burners

Writer: admin Time:2021-09-18 00:00 Browse:

The biomass particle burner has high efficiency energy saving, low-carbon environmental protection, and the simplicity of the characteristic biomass particle burner function is highly efficient, and the integrated is integrated. Then the operation of single fire burners
	Mode of operation of single fire burners

Mode of operation of single fire burners
Let's introduce how the single fire burner is going. The working mode at the time of low nitrogen burner is started - stopped, once the adjustment setting of the burner is completed, the output power of the burner is fixed (may vary slightly due to the change of the external conditions), the burner only one Work points, start and stop of the burner are controlled by TC temperature control or pressure switches on the control loop. After the low nitrogen burner is activated, if the temperature or pressure of the heated object is lower than the TC setting value, Tc is automatically closed, the burner is started. When the temperature or pressure of the heated object is higher than the TC setting value, Tc is automatically disconnected, and the burner is stopped. When the temperature or pressure of the heated object is reduced to below the TC setting, the TC is re-closed, and the burner is automatically re-run. Single fire combustion machine is suitable for boilers, heating furnaces, incinerators, paint rooms, kitchen fire furnaces, hot air furnaces, die-casting machinery, drying equipment, industrial kiln, etc., the effect is good. Power stability. Low nitrogen burner is not exceeding 70 ° C under normal conditions, otherwise it is taken to take cooling and insulation measures. Moreover, the use of burner should avoid homogeneous environments. For one year, a nap is changed, and the elastic coupling and rubber parts on the coupling are replaced one year and a half. Avoid aging of accessories, cause unsafeness. At the same time, it is necessary to ensure that foreign objects enter the airway to prevent accidents. It is also necessary to regularly check the burner, impeller, flame detector and ignition electrode, remove oil and carbon. In particular, the flame detector should be kept clean and should not be sealed. The oil pressure is appropriately adjusted according to the hydraulic indicator. It is also necessary to check whether the connection of the burner and the components is rugged, there is no loose, and the position has no change to ensure the normal operation of the burner. As long as you regularly check the operation of the burner, do a good job in the maintenance of burner, it will greatly improve the working efficiency of the burner, bringing a more durable operational environment.